LIBERO CS

Get a Quote
WHO PQS temperature logger

Recognised single-use monitoring for vaccines and medical cold chains

  • WHO PQS option
  • Single-use logger
  • Configurable alarm profile
  • Electronic report
  • Healthcare cold chain
  • Minimum order: 250 units

The WHO pre-qualified single-use data logger provides a documented temperature history for vaccines and other regulated healthcare products during transport and temporary storage. It is selected for programmes that require a WHO PQS-listed monitoring option and a clear, standardised receiving process.

Minimum order quantity: 250 units. Use + or − to adjust one unit at a time.

Introduction

LIBERO CS is a single-use PDF temperature data logger designed to simplify cold-chain shipments for products with known stability data. A single device can be configured with the correct profile for a specific product, removing the need to keep multiple logger types in stock.

Before shipment, users can apply the required configuration profile and add shipment information. During transport, the logger records temperature data and evaluates the configured alarm criteria. At destination, the large display immediately shows an OK or ALARM status to support fast product-release decisions.

Multi-Level Alarm Monitoring

The logger supports up to eight programmable temperature alarm levels. Alarm evaluation can be based on single or cumulative delays, mean kinetic temperature (MKT), defined temperature thresholds, or total duration and run time. This allows monitoring profiles to be matched to the known stability limits of individual products.

Automatic PDF Report

When the logger is connected to a USB port, the built-in PDF generator automatically creates a secure evaluation report containing the complete trip data. The report includes logger and configuration information, minimum, maximum and average values, alarm statistics, a temperature graph with alarm limits, and a configurable text area for shipment instructions or recipient information.

The generated report follows the PDF/A standard for long-term document preservation and supports cold-chain documentation requirements, including FDA 21 CFR Part 11 workflows.

Simple Operation Without Additional Equipment

LIBERO CS requires no separate reader or analysis software for routine shipment use. The secure Start/Stop button, automatic expiry-date management and clear multifunction display make it suitable for use by logistics teams and third parties.

Display and Status Information

The multifunction LCD shows configuration, start, run and stop status, current temperature, configuration profile identification, and a prominent OK, ALARM or blank condition. This allows receiving personnel to assess shipment status immediately before opening the detailed report.

Cold-Chain Database Compatibility

Generated reports can be forwarded to the sender or imported into liberoMANAGER, ELPRO's cold-chain database, for storage, analysis, release-status management and workflow automation. Embedded report data may also be accessed and exported using elproVIEWER where required.

Applications

LIBERO CS is intended for cold-chain monitoring applications where products have defined stability data or permitted time-and-temperature excursions. Typical uses include pharmaceuticals, vaccines, clinical supplies, biotechnology products and other temperature-sensitive shipments.

Specifications

ModelLIBERO CS
TypePDF data logger with multiple alarm levels
Application AreaCold-chain monitoring for products with stability data or permitted time-and-temperature excursions
Recording ModeSingle use, Start/Stop mode
Operating Range−30°C to +70°C
Measurement Accuracy±0.4°C from 0.0°C to +25.0°C; ±0.5°C from −10.0°C to −0.1°C and +25.1°C to +35.0°C; ±1.0°C from −30.0°C to −10.1°C and +50.1°C to +70.0°C
Typical Core Accuracy±0.3°C for 95% of units in the 0.0°C to +25.0°C core range
Resolution0.1°C
Measurement Interval1 to 60 minutes, user programmable
Memory Capacity24,200 measurement values; approximately 168 days at a 10-minute interval
Expiry and Battery ManagementMay be started at any time during shelf life; automatic expiry-date management prevents starting after expiry
Battery TypeButton cell contained in equipment, UN3091, exempt from DGR declaration
Calibration CertificateILAC/NIST/ISO 17025 traceable production calibration certificate
Programmable AlarmsUp to 8 temperature alarm levels with single or cumulative delays; MKT alarm; 2 temperature thresholds with alarm delay; duration/run-time alarm
Start-Up Delay0 minutes to 24 hours
DisplayMultifunction LCD, 23.5 × 23.5mm, with large OK and ALARM indicator
Display FunctionsConf, Start, Run and Stop status; current temperature; OK, ALARM or blank; configuration profile identification
ReportAutomatic built-in PDF/A report with embedded data, customizable title and filename, shipment-information text area, statistics, logger details and temperature graph with alarm limits
TraceabilityUnique ID number traceable to component level
Case MaterialABS plastic
Dimensions96 × 37 × 11mm
Weight38g
Protection RatingIP54
CertificationsCE, EN12830, EMC, RTCA DO-160, RoHS, WHO-PQS and Safe Transport of Chemical Goods