Atlas Log-30 Temperature Data Logger
Flexible monitoring for food, vaccines, pharmaceuticals and controlled storage
- Single-use or multi-use
- -30°C to +70°C
- External buffered probe
- Up to 35,000 readings
- Automatic PDF/CSV reports
- Minimum order: 50 units
Atlas Log-30 is a configurable USB temperature data logger with an external probe, real-time LCD display and automatic PDF/CSV report generation. It is designed for cold-chain transport, refrigerators, freezers, vaccine storage, pharmaceuticals, food and other temperature-sensitive applications.
Introduction
Atlas Log-30 is a configurable temperature data logger that can be supplied for single-use or multi-use monitoring. Its external temperature probe extends into the monitored space while the main logger remains easy to view and operate. The device measures from -30°C to +70°C and displays the current temperature, running status, alarm condition, battery level, and maximum, minimum and average values on its LCD screen.
The logger is suitable for shipping containers, air and sea freight, distribution centres, refrigerated storage, freezers, medical refrigerators, vaccine cabinets and laboratory environments. Its configurable recording interval, start delay and alarm points allow each deployment to be adapted to the required transport or storage protocol.
After monitoring, the built-in USB connection enables the logger to generate irreversible PDF, CSV or combined PDF-and-CSV reports directly on a Windows or Mac computer. A temporary-report mode allows data to be reviewed while the logger continues recording.
Key Features and Benefits
Single-use or multi-use operation
Choose the operating mode that matches a one-way shipment or a reusable monitoring programme.
External temperature probe
Supports flexible cable and probe options for refrigerators, vaccine storage, sealed doors and other specialised environments.
Real-time LCD display
Shows current temperature, alarm status, battery level, running state and maximum, minimum and average values.
Configurable alarm system
Supports up to six alarm points, nine event marks, LCD alarm indication and an optional buzzer.
Automatic reports
Generates PDF, CSV or combined reports through USB without requiring report-reading software.
Temporary reports
Export and review an interim report without ending the active monitoring session.
Replaceable battery
The CR2450 battery can be replaced for continued multi-use operation.
Buffered probe option
A propylene-glycol buffered probe can reduce the effect of short air-temperature changes in vaccine and medical refrigerators.
How the Product Is Used
Applications
Atlas Log-30 is designed for temperature monitoring across cold-chain transportation and controlled storage, including:
- Vaccines, biologics and pharmaceutical products
- Medical refrigerators, vaccine cabinets and walk-in coolers
- Blood cold chain, biological samples and diagnostic reagents
- Food, frozen food and temperature-sensitive ingredients
- Refrigerated trucks, shipping containers and air or sea freight
- Distribution centres, warehouses, freezers and laboratories
- Applications requiring a flexible ultra-thin cable through a sealed refrigerator door
Probe type, cable material, cable length, operating mode and alarm configuration should be selected for the specific application. Contact Gee Gee Data Monitoring System EMS (Pty) Ltd for assistance.
Atlas Log-30 Specifications
| Model | Atlas Log-30 |
|---|---|
| Type | Single use or multi use |
| Temperature Range | -30°C to +70°C |
| Temperature Accuracy | ±0.5°C full scale |
| Resolution | 0.1°C |
| Memory Capacity | PDF: maximum 35,000 readings; PDF & CSV: maximum 20,000 readings each |
| Logging Interval | 1 minute to 24 hours |
| Start Delay | 0 minutes to 24 hours |
| Alarm Points | Up to 6 |
| Marks | Up to 9 |
| Alarm Type | LCD alarm indication; optional buzzer approximately 60 dB at 3 m |
| Report Format | Automatic PDF, CSV or PDF & CSV |
| Connection | USB; NFC optional |
| Battery | Replaceable CR2450 |
| Protection Grade | IP65 |
| Compatible Operating Systems | Windows and macOS |
| Dimensions | 96 × 44 × 15 mm |
| Certifications | CE, RoHS and EN12830; WHO PQS E006/TR05.1 compliant configuration available |
| Probe Options | Flexible ultra-thin cable, PVC, Teflon or silicone insulation; sharp, blunt or buffered probe options |
Freshliance Tools
Freshliance Tools is the PC configuration, data-retrieval and analysis software used with Atlas Log-30. When the logger is connected through USB, the software automatically detects it and displays the device ID, battery condition, operating mode, logging interval, start mode and alarm settings.
Before deployment, users can configure the single-use or multi-use mode, recording interval, start delay, alarm thresholds, temperature unit, time zone, report format and optional buzzer. Recorded data can be reviewed as graphs and tables, with maximum, minimum, average and MKT statistics available for quality and compliance review.
The software supports report export in PDF, CSV, TXT and PNG formats, multiple languages and comparison of data from several devices on one chart. The generated automatic PDF/CSV report can still be opened directly from the logger without Freshliance Tools.
Complete configuration
Set operating mode, interval, delay, alarms, marks, units, time zone and report preferences.
Automatic USB detection
Connect the logger and view its identity, battery, status and configured parameters.
Data analysis
Review graphs, detailed logs, alarm excursions and maximum, minimum, average and MKT values.
Flexible exports
Export PDF, CSV, TXT or PNG and compare multiple logger records on one chart.